Gentron 7200w rated 10000w Drain the fuel tank and refill it with new fuel, then try to start the generator again. Confirm the fuel level Some generators will not start at all if the fuel tank is almost empty. On 5/11/2011 at 5:18 PM, F271186 said: Our Onan Micro 4000 gas generator starts fine but won't continue to run. If old fuel was left in the small engine for a long time, some of the volatile ingredients may have evaporated, leaving a thicker, stickier product that is more like varnish or shellac. I have changed oil, spark plugs, given carburetor a several shots of carb cleaner. when empty and 56.5 lbs. Even clogged carburetors can be held responsible. But overloading is a common issue with a simple fix so before you start taking it apart, try unplugging some unnecessary devices and see if that solves the problem. Sep 28, 2020 Kohler 10CC61 Backfed and now wont stay running after letting off start button. Bad spark plug. If Check that the pipe sizing is correct for your application. In this post, we have aimed to help you fix some common issues you might face during the course of using your DuroMax/DuroStar generator. While some RV generators will run until the fuel tank has nothing but fumes, the Onan models tend to stop working when youre down to a quarter tank. At the pin in the plug (the wiring harness side), locate wires P1-15 and P1-20. Dirty air filter. The carburetor may be clogged or filled with bad gasoline. cruiserdar; Oct 2, 2011; Kohler Generators; Replies 9 Views 4,118. The only solution is to drain the old fuel out of the main float bowl and clean the entire carburetor with a carbohydrate cleaner. The propane generator wont stay running. I am getting good fuel flow beyond the fuel filter to the carburetor, so it isn't the fuel filter. An electric cutoff may be operated from an oil pressure switch. Posted By: BCBigfoot106 on 12/30/08 02:16pm I have a Onan 2500 LP generator in my Bigfoot camper. A faulty board can reduce or eliminate that AC voltage supply. If you try starting the generator without the load connected, itll likely not start. Generator won t stay running. The control panel and voltage meters can also break down. Best Portable Generators. Why Wont My RV Generator Start And How Do I Fix It?Low Oil Level. Like many mechanical systems, your generator needs oil to keep things running smoothly. Battery Issues. The battery is an integral part of the generator system. Lack Of Fuel In RV Fuel Tank. Old Fuel Or Not Enough. Parts Should Be Replaced. Its Just Old. I have had the same issues before and these suggestions worked for me. Therefore, a 500-gallon tank will run for a week without stopping, while a 1000 gallon one will operate for two weeks before you refill the tank. People always want to blame the fuel system when a propane fueled engine won't start/run but in very few cases is it really the fuel system. Thread starter Davesr; Start date Sep 28, 2020; D. Davesr Registered. Read the manual and check the equipment. Most problems with generators occur from improper use. Check the temperature of the generator; if it's too high, it will cease to function. This is a safety feature. Check the oil level and air filter. Change the oil if it is has not been changed in several months. Examine the device connected to the generator. when full. Propane is rather fussy when it comes to ignition so you MUST have a good hot spark. We shut everything off. Vapor lock. You have to override this shutoff until the engine is up to speed. In some cases, its just a blockage in the system. Kohler 5 KW propane generator won't stay running after I release start button. This often means ignoring the original spark plug gap specification and instead setting the gap to 0.020 of an inch. Open all doors and windows on the generator in order to allow fresh air into the engine compartment. Source: lib.nvspca.org. Open up your generators air filter housing and check to see if there are any clogged bits on your spongy element within your air filter. In that case, go Tip 02. 3.) If your Onan generator isnt running, it may be because fuel levels are too low. P. M. Sticky Switch. If your Onan generator isnt running, it may be because fuel levels are too low. When a generator is 2. Propane generators generally have an oil trap somewhere between the propane tank and the generator's LP vaporizer/carburetor. Water levels in the radiator can also be why your generator won't stay running. - stepping motor acting up which right now would be from lack of gas supply. 1. I can't rely on it. Sometimes in hot weather (above 97-98 degrees F), your generator will develop something called: a vapor lock. Set your meter to ohms, and connect the RED lead to a clean ground. The choke being closed can cause the engine to get too much fuel on start up. Make sure all connections between panels are secure by tightening screws or bolts.. . Tanks that have not been filled multiple times. Its possible that your generator wont keep running due to a fuel or air delivery system issue. Check that trap to be sure it contains no condensation that looks a bit like waxy coffee. (at least 4 times.) Let it run 15-20 minutes then remove all the loads and let it There are, however, a few things you might want to look at before you go and get yourself a new one. Flawed regulator. more than likely its one of 2 issues. will have air trapped inside of them causing the fuel mixture in the carburetor to be too lean. Now, remove the main bolt/nut at the bottom-center of the bowl and remove the bowl. The generator is low on fuel. There can be many reasons behind your generator not running properly. tested for that by disconnecting the terminal from the post on the oil. They are: Faulty control boards Sticky switches Bad regulator Ground or short in the rotor Damaged wiring The instructions say to turn off the load. Gas Problems: The most important thing for a generator to start and run is sufficient gas in its tank. when full. The purpose of this valve is to automatically shut off the flow of propane if the engine stops for some reason. Cleaned the carb and replaced the shutoff solenoid. A steel propane tank weighs around 36 lbs. This is why the smell of propane gas is only noticed when fittings allow gas to escape. The choke of any engine should be set to closed during startups and then moved to open once the engine warms up. Make sure this part isnt torn as well. Then, slowly open the cylinder valve to check for leaks, it will bubble slowly if there is a leak. This is when the gasoline in a fuel pump vaporizes and the pump begins to push gas (or vapor)! This thing has given me nothing but problems. Choke is too open/closed. It was in non running condition when I got it. Propane Generator Hard To Start 1. Water levels. I went thru the fuel system, replaced fuel lines, fuel filter and new fuel pump. We got a fault of 38 which according to the manual is an overload situation. Now I'm stumped. While the generator is running, engine vacuum closes a switch that causes the solenoid valve to be energized and hence to open. Gentron 6000 Watt Propane Generator with Electric Start 3 Questions. - lack of gas pressure. If everything seems okay but your generator still wont start, check to see if there is an electricians circuit breaker tripped in your area. The most common cause of a carburetor becoming clogged is by leaving fuel residue in the generator over an extended period of time. Short or ground in the rotor. When the weather is below zero it doesn't want to start. To solve this, you 2. Depending on the style of your generator, this choke lever may be positioned in a few different places. The solution is to make it a habit to check the water levels monthly. Low oil sensor is malfunctioning. pressure switch and making sure there was sufficient oil in the. crankcase started the generator. Unplug the control board. In the middle of a 7,300 mile circuit of North America in 2011, we discovered that the Onan MicroQuiet 3600LP generator in our 2006 Itasca Navion wouldn't start. If it still wont start, replace the spark plugs. The propane generator wont stay running. However, you should check the fuel level of the propane if your generator stops working. If you are sure there is enough oil, disconnect the wire to the oil sensor and see if the engine keeps running. Generator Will Shut Off After Running for a Minute; Type Fuel For e3200R Portable Inverter Generator; Does Yamaha Make Motor of the A-iPower 2,000-Watt Inverter Generator w/ Parallel Kit # 289-SUA2000I; SUA2000i Spark Plug Replacement Options; Troubleshooting An A-iPower 2,000 Watt Portable Inverter Generator That Won't Start Holding the primer button in for a longer period of time can cause engine flooding. Youll then need to take immediate action. If there is no voltage on the field flash, the board could be defective. Overloading is a really common cause behind this issue. There is fuel to and beyond the fuelock filter. It will not stay running. Among the causes that lead to the Onan generator starts then shuts down issue, The Onan Marquis requires sufficient oil pressure to keep running, so carefully check the oil level. But you can fix this. First, shut off the fuel valve. Here are the potential culprits: Sticky switches. 16. Posted December 22, 2017. 3) The choke lever is in the wrong position. There is another possibility here, but it should be showing a code 47, not a 37. During starting, the engine governor will keep the throttle wide open, and this combined with the relatively low RPMs while starting will prevent enough vacuum from being developed to operate the the vacuum switch reliably. If it does, then try plugging in devices one by one to ensure a reasonable load. Hard to start and once running will not stay running on less than half choke. Before the generator's engine starts, there is no oil pressure. Replace the Carburetor Repair Kit. I recently acquired a Generac Gp15000e model 0057341. To fix the generator, youll need to know more. If it does, drain it, clean it out and blow out the line to the generator set. If it is correct, then it may be a faulty oil pressure switch, or it could also be stuck in the open position. The propane-powered generator will run on propane until this fuel is exhausted. You could have a bad oil sensor. DuroMax Generator Will Not Stay Running Small Engine Repair - YouTube. Shuts off in apx 1 min. later today it could be from overheating. Power. When it did, the generator shut down. 2.) Carburetor is clogged. If there is no voltage on the AC output, proceed to check the voltage on the field flash via the control boards pin. Damaged wiring. Holding the primer button in for a longer period of time can cause engine flooding. The average capacity of propane-powered generators is 500-1000 gallons, and they usually burn 2 to 3 gallons per hour. If it looks dirty, use carb cleaner to 3. An aluminum propane tank weighs around 23 lbs. The code flashed by the generator translated to "Battery low or cranking speed too low" which we knew for a fact was not the problem. The choke being closed can cause the engine to get too much fuel on start up. We had not run it in many months (we are infrequent generator users). Second you said that you just had the tank filled, sometimes the fuel jockey well shut off the esd for generator propane. Common solutions for: Generator won't stay running 01 - Carburetor The carburetor might be clogged or have bad fuel in the float bowl. I did get it to sputter on starting fluid. if its not raining, take the front cover off and make sure the When the flow of fuel to the carburetor is cut off, the engine will stall. It now starts on its own, but idles up to a high rev then shuts down. That possibility is if one of your magnetos is bad. Starting fluid in the carb will keep it running, but it does not run off the propane tank. The Fix. A clogged air filter, poor fuel quality, a carburetor stuck on choke or a bad spark plug could all lead to this result. 1. As soon as this occurs, check the voltages on the AC output with your multimeter. Reasons Your Generator wont start. That will cut off the fuel flow and cause it to stop running. If the fuel is left there for too long it can create a thick, sticky residue-like substance. The first and most important step is to make sure that you are using a propane tank that has been refilled multiple times. Reassemble and try again. Once a month is good, but you should let it warm up a few minutes, start adding loads up to at least half capacity, maybe 3/4 capacity. You should try to turn on and start the Onan generator. Make sure the rocker switch that controls the engine is in the On position.Check the fuel; the engine won't start if the engine is out of fuel or if the fuel is stale or contaminated with water. Bad fuel can contaminate the carburetor. The engine on a power washer that won't start may also need a good tune-up so it will start easily. More items Second, check to see if there's an electric or vacuum operated cutoff valve. Common solutions for: Generac Generator won't stay running 01 - Carburetor The carburetor might be clogged or have bad fuel in the float bowl. Without the proper water level, engines can "run hot," causing some parts of the engine to fail and break down. The fuel valve controls the amount of fuel from the tank into the combustion chamber for combustion. Using other fuel types for your generator has several advantages:Shelf life. Gasoline will eventually go bad if stored for a long period of time without additives while propane wont. Storage. It is easier to store large amounts of propane. Availability. In emergency situations, there is usually a higher demand for gasoline than propane. Less noise. Clean burning. Durability. Unlimited Source. This not the best way to "exercise" a genny. Clark C300-30 LP fueled - won't stay running. Generator Will Shut Off After Running for a Minute; Type Fuel For e3200R Portable Inverter Generator; Does Yamaha Make Motor of the A-iPower 2,000-Watt Inverter Generator w/ Parallel Kit # 289-SUA2000I; SUA2000i Spark Plug Replacement Options; Troubleshooting An A-iPower 2,000 Watt Portable Inverter Generator That Won't Start Check the fuel levels. It may seem obvious, but its worth checking whether your generator has gasoline in the fuel tank. Drain the bad fuel, clean it By gas, we mean the fuel type your generator is using. It shouldnt be much. When we tried to restart the generator, it will come on, run for 10-15 seconds or so and then shut off. Overload The safest way to start and use a generator for power generation or other task is to start it, let the roar become smooth then connect the load. (Fixed) Generator Runs for a Few Seconds then Stops 14 Common Causes 1. While some RV generators will run until the fuel tank has nothing but fumes, the Onan models tend to stop working when youre down to a quarter tank. If it then shuts down, it normally indicates a low oil level. If old fuel was left in the small engine for a long time, some of the volatile ingredients may have evaporated, leaving a thicker, stickier product that is more like varnish or shellac. Check the fuel levels. My tech tells me my primer switch needs replacing and is why my unit wont stay running. So if the tank feels unusually light, then its likely empty. Sometimes battery issues, sensor failure, or bad exhaust cause this too. Some of the reasons your generator wont stay running include the following: 1. Lets get your generator up and running! In some rare cases, its the vibration from the generator that can cause the fitting to leak. Issue C. Generator won't stay running Troubleshoot 01: Carburetor One possible answer is that the carburetor is clogged. The oil sensor is ignored until the engine has a chance to come up to speed. If that does not work, it may mean replacing the entire carburetor altogether. The brushes were bad.. Other things that can cause this are a bad circuit board (Already mentioned) and a loose wire. The generator also requires enough AC voltage to keep it rotating. Clogged or closed fuel valve. 1. A couple of things come to mind, first thing-there is a plastic fuse holder just above the manual start button, check the fuse. when empty and 69.5 lbs. The problem was no 120 volt.. Check the Air Filter Online research eventually revealed a common cause: a restriction of the "regulator vent hose" on the generator. Overloading The most common reason behind this problem is the overloading of the generator. Generator will start but won't keep running. Bad fuel in the float bowl will do the same thing. Clean this out with a soft brush or scrubbing device since if you used water or any other liquid it might affect the element within your plastic housing. Check the spark plug Spark plugs can wear out even if they visibly look fine. Defective control board. The fix is to introduce more air to the combustion chamber. Is there reset switch? Source: lib.nvspca.org. The popular DuroMax/DuroStart generators that you will find include the DuroStar DS4000S 3,300-Watt Generator, DuroMax XP10000E 8,000-Watt Generator, DuroMax Elite MX4500E 3,500-Watt Generator. Fuel valve or line is clogged. Put simply: A generator will blow out black smoke from the exhaust when it is running rich from the ideal (more fuel relative to the amount of air). Tip 02. If your carburetor bowl has a drain screw, use a 10mm wrench to open it and allow any fuel in the bowl to drain out. Dec 11, 2011. This is a discussion in the forum 'Design & Engineering' on Forkliftaction.com, the global platform for anything forklifts and materials handling. This wont be an issue if your generator runs on propane. If its not opened when running the generator, the engine will run out of fuel and shut down.